External stiffened steel plates retrofitted onto non-seismically designed reinforced concrete beam-column joints improved joint shear strength and significantly delayed structural failure under horizontal cyclic displacement tests without axial column loads. I

Illustrative imageIllustrative image

External stiffened steel plates retrofitted onto non-seismically designed reinforced concrete beam-column joints improved joint shear strength and significantly delayed structural failure under horizontal cyclic displacement tests without axial column loads. In reinforced concrete moment-resisting frame structures, beam-column intersections resist both gravity and lateral demands by transferring critical internal forces. Across older buildings erected prior to the codification of modern capacity design principles in standards such as ACI 352R-76, NZS 3101:1982, and Eurocode 8, these joint cores typically lack transverse shear reinforcement. Historical reconnaissance following major seismic events, including earthquakes in Kocaeli, Bam, Wenchuan, Christchurch, Tohoku, Emilia, Gorkha, Mamuju-Majene, and Noto, has confirmed that omitting shear stirrups within the joint region precipitates premature diagonal shear cracking, brittle failure mechanisms, and hazardous soft-storey collapses.

To counter these structural vulnerabilities without necessitating invasive interventions such as deep structural demolition, complete concrete jacketing, or complex post-tensioning setups, researchers Lorenzo Bizzarri, Caterina D’Agostino, and Amedeo Gregori investigated a surface-applied retrofit system. Conventional strengthening techniques involving carbon fiber reinforced polymers, fabric reinforced cementitious matrices, steel cages, or continuous concrete jackets frequently require the demolition of surrounding floor slabs, partition walls, and architectural finishes, or they face limitations associated with anchor debonding, environmental matrix degradation, and high installation labor. The alternative system developed in this investigation utilizes an external thin steel plate stiffened by diagonal ribs aligned directly along the expected compressive diagonal strut of the joint core, reinforced at the outer perimeters with substantial corner angle profiles to prevent localized edge crushing.

The experimental campaign examined four full-scale reinforced concrete sub-assemblies representing internal wall joints and exterior corner joints typical of multi-storey frames. Each test configuration paired an unreinforced control specimen against an identical specimen equipped with the external steel plate retrofit. The frame geometry comprised beams and columns measuring 300 mm by 500 mm in cross-section, with an overall column height of 3200 mm and a beam length of 4500 mm. Boundary conditions placed roller supports at beam ends and a pinned hinge at the base of the column to reproduce inflection points corresponding to mid-span frame locations under seismic lateral sway. To simulate the three-dimensional transverse confinement and geometric boundary effects typical of real buildings, a perpendicular stub beam measuring 300 mm by 500 mm in section and 600 mm in length was cast into the joint core.

Material characterization established that the structural concrete achieved an average cylindrical compressive strength of 29.3 MPa at 28 days, accompanied by an elastic modulus of 30,373 MPa and a mean tensile strength of 2.85 MPa determined according to Eurocode 2 equations. Longitudinal reinforcing bars consisted of B450C steel with a characteristic yield strength of 450 MPa and an ultimate tensile strength of 540 MPa. Column longitudinal reinforcement featured four 24 mm diameter bars, whereas beam elements incorporated two 24 mm bars and three 20 mm bars per face, confined along the member spans by 10 mm stirrups spaced at 100 mm. The joint panels intentionally omitted all internal stirrups to reproduce pre-seismic construction deficiencies. The external plates were fabricated from S355J2W weathering Corten steel having a yield strength of 355 MPa and an ultimate strength of 490 MPa.

The physical retrofit assembly consisted of a 5 mm thick main steel plate measuring 515 mm by 780 mm, stiffened along its primary diagonals by 6 mm by 30 mm welded flat ribs and bordered by 200 mm by 200 mm by 8 mm corner angle profiles. Mechanical attachment relied on eight pre-drilled steel chemical anchors measuring 20 mm in diameter and 300 mm in length, embedded 250 mm deep into the concrete core. A 10 mm bedding layer of commercial premixed cementitious mortar was applied between the prepared concrete surface and the steel plate to compensate for surface roughness and guarantee uniform bearing contact. Installation involved rigorous surface cleaning, drilling through plate templates, injecting chemical resin, inserting fasteners, torquing nuts to squeeze out entrapped air through auxiliary vent holes, and allowing the interface mortar to cure for 30 days prior to physical loading.

Quasi-static horizontal cyclic testing was conducted by displacing the top of the column using an electrically driven actuator at a constant speed of approximately 0.25 mm/s while recording resistance forces with a 500 kN load cell. To establish the most demanding baseline for joint shear distress, researchers applied zero axial compression to the column, deliberately excluding the beneficial axial pre-compression that normally widens diagonal concrete compression struts. Building upon displacement steps adapted from the ACI 374.1 protocol, cyclic increments of 3 mm to 7 mm advanced the sub-assemblies to drift ratios between 2.2% and 2.8%, corresponding to lateral displacements of plus or minus 70 mm to 90 mm, followed by a monotonic push to evaluate post-peak ductility and maximum capacity without test interruptions.

Experimental cyclic hysteresis loops demonstrated that installing external steel plates produced substantial gains in peak load capacity and overall energy dissipation. The unreinforced control wall joint reached a maximum horizontal shear force of 226.20 kN at an ultimate drift ratio of 0.046, whereas the externally reinforced wall joint achieved 259.96 kN at an ultimate drift ratio of 0.059. This performance represents an increase of 14.92% in peak shear strength and an increase of 28.26% in ultimate deformation capacity. For the corner joint configuration, the unreinforced specimen attained a peak horizontal shear force of 127.87 kN at an ultimate drift ratio of 0.046. The retrofitted corner joint registered a peak capacity of 136.95 kN, achieving an ultimate drift ratio of 0.125, which reflects a 7.11% enhancement in maximum shear force alongside an exceptional 171.73% surge in ultimate lateral drift capacity.

Panel shear distortion recordings derived from pairs of crossed diagonal linear variable displacement transducers demonstrated that the retrofitting system markedly curbed localized panel distress. During the cyclic loading envelope, peak shear strain across the wall joint core was reduced from 1.24% in the unreinforced specimen down to 0.55% in the retrofitted specimen, marking a 56% strain reduction. In the corner joint sub-assemblies, maximum core shear strain decreased from 3.12% to 1.64%, representing an approximate 47% reduction. Post-test removal of the steel plates confirmed that while unreinforced specimens suffered wide diagonal shear fractures and severe concrete cover spalling within the joint core, the retrofitted joints exhibited narrower, distributed hairline cracks, shifting ductile plastic hinge formation into the adjacent beam spans.

Complementary three-dimensional non-linear finite element simulations performed in MIDAS FEA NX employed a Concrete Smeared Crack formulation, applying the JSCE2017 compressive law, the Hordijk tensile softening model, and the crack-band fracture energy regularizer of Bazant to avoid mesh dependency. Steel rebars were represented by embedded elasto-plastic hardening elements, while plate components and fasteners were modeled using solid and beam elements with elastic-perfectly plastic constitutive definitions. To establish analytical bounds given uncharacterized interface friction, simulations evaluated two bounding interface contact conditions: fully bonded perfect adhesion and pure fastener engagement without plate-to-concrete surface adhesion. Monotonic pushes under displacement control with a Newton-Raphson solver accurately bracketed the experimental load-displacement envelopes and peak shear capacities.

The numerical parametric comparisons revealed that interface adhesion governs internal stress distribution and failure modes. Under perfect adhesion, simulated wall joint peak shear reached 265.63 kN, exceeding baseline unreinforced response by 19.66%, while the zero-adhesion model reached 245.45 kN, reflecting a 10.57% gain against experimental peaks of 259.96 kN. For corner joints, simulated capacity reached 152.26 kN with perfect adhesion and 133.03 kN without adhesion, bracketing the experimental value of 136.95 kN. Under perfect contact, stresses spread evenly across the plate face, driving steel yielding primarily around plate corners and fastener apertures while anchors remained elastic. In the absence of interface adhesion, load transferred directly to the anchor bolts, causing premature fastener yield while plate stresses remained substantially lower and predominantly elastic.

Despite the substantial structural enhancements demonstrated across both joint topologies, the authors highlighted several engineering qualifications and physical limitations. Because permanently bonded external plates conceal underlying concrete, routine visual inspection and post-earthquake damage evaluation of the internal joint core become challenging. Structural tuning remains constrained by anchor quantities, as drilling additional holes risks compromising concrete integrity, while lengthening corner angles or thickening diagonal ribs adds weight that hinders concealment beneath standard architectural plaster. Furthermore, testing examined single full-scale specimens per configuration under unidirectional loading without column axial force, floor slabs, or masonry infill panels, underscoring the necessity of evaluating long-term mortar shrinkage, creep, and environmental durability prior to broad structural implementation.

Subject of Research: External steel plate retrofitting of non-seismically designed reinforced concrete beam-column joints under cyclic loading

Article Title: Experimental and numerical investigation of non-seismically designed externally reinforced RC beam–column joints

Article References: Bizzarri, L., D’Agostino, C., & Gregori, A. (2026). Experimental and numerical investigation of non-seismically designed externally reinforced RC beam–column joints. Results in Engineering, 32, Article 114348. https://doi.org/10.1016/j.rineng.2026.114348

Image Credits: AI Generated

DOI: 10.1016/j.rineng.2026.114348

Keywords: reinforced concrete, beam-column joints, seismic retrofit, cyclic loading, steel plates, shear capacity, structural ductility, drift ratio, finite element modeling, bond-slip interaction, concrete smeared crack, earthquake engineering, full-scale testing, crack propagation, structural rehabilitation, non-seismic design, anchor fasteners

News Source: Denise Maddox. (November 25, 2026). External Steel Plates Boost Shear Strength and Ductility in Reinforced Concrete Joints. Scienmag.